RESPON STRUKTUR TERHADAP BEBAN DINAMIK GEMPA PADA RUSUN MAHASISWA INSTITUT TEKNOLOGI PADANG DENGAN SHEARWALL

  • Ibnu Hanif Sudarmaka Universitas Putra Indonesia “YPTK” Padang
  • Rafki Imani Universitas Putra Indonesia YPTK Padang
  • Rita Nasmirayanti Universitas Putra Indonesia “YPTK” Padang
  • Kharisma Permata Sari Universitas Putra Indonesia “YPTK” Padang
Keywords: shearwall, ITP Padang, axial load, L-frame, displacement

Abstract

Rusun Mahasiswa ITP Padang was originally designed without using a shearwall, but in practice, it was changed to using a shearwall with L-frame type. This study aims to analyze the effect of using shearwall on the columns and beams of Rusun Mahasiswa ITP Padang. The results showed that the use of shearwall with L-frame type on columns caused a 3% decrease in the axial force on the column, up to 90% in cross-sectional force, and up to 84% in moment load reduction. Meanwhile, the beam elements can reduce the shear force by up to 24%, and the moment load can be reduced by up to 35%. The deviation between floors in Rususn Mahasiswa ITP Padang has met the required limit, where the deviation values for the x direction (Δx) and y direction (Δy) are smaller than the permit deviation (Va).

References

Agus, A., & Maimunnah, S. (2021). Respon Gempa Gedung Beton Bertulang 20 Tingkat dengan Variasi Tata Letak Dinding Geser. Jurnal Teknik Sipil ITP, 8(2), 59–65.

Andalas, G., Suyadi, & Husni, H. R. (2016). Analisis Layout Shearwall Terhadap Perilaku Struktur Gedung. JRSDD Journal, 1(1), 492–502.

Astuti, P. (2015). Pengaruh Penambahan Dinding Geser (Shear Wall) pada Waktu Getar Alami Fundamental Struktur Gedung. Jurnal Semesta Ilmiah Teknika, 18(2), 140–146.

Badan Penanggulangan Bencana Daerah Kota Padang (BPBD Kota Padang). (2019). Mengenang Gempa 2009 di Kota Padang. Artikel online: https://bpbd.padang.go.id/ konten/mengenang-gempa-2009-di-kota-padang/. Diakses tanggal 17 Agustus 2023

Elfitri, R., Suraji, A., & Hakam, A. (2016). Kontribusi Kontraktor Terhadap Pengurangan Resiko Kegagalan Bangunan Akibat Gempa Di Kota Padang. Jurnal Rekayasa Sipil, 12(1), 49–58.

Hanif, B, A, & Buwono, H. K. (2014). Analisis Pengaruh Shear Wall Terhadap Simpangan Struktur Gedung Akibat Gempa Dinamis. Jurnal Konstruksi, 5(2), 79–101.

Harahap, M. F., & Fauzan, M. (2019). Perilaku Dinamik pada Struktur Apartemen Metro Galaxy Park terhadap Beban Gempa. Jurnal Teknik Sipil dan Lingkungan, 4(3), 195–206.

Kalangi, H. T., Tanijaya, J., & Thetrawan, M. (2021). Analisis Pengaruh Penempatan Dinding Geser Terhadap Perilaku Dinamik Struktur Bangunan. Prosiding Seminar Nasional Riset dan Teknologi Terapan (RITEKTRA) 2021 Menuju Society 5.0: Teknologi Cerdas yang Berpusat pada Manusia (Bandung, 12 Agustus 2021).

Kurniawan, H., Imani, R., & Sahputra, D. E. (2022). Identification of Damage Levels of Residents' Houses Due to Earthquake in Pasaman 2022. Civil Engineering Collaboration Journal (CEC), 7(2), 73–79.

Liliwarti, L. (2018). Informasi Titik-titik Likuifaksi akibat Gempa Bumi di Kota Padang. Jurnal JIRS, 15(1), 17–23.

Majore, B. O., Wallah, S. E., & Dapas, S. O. (2015). Studi Perbandingan Respons Dinamik Bangunan Bertingkat Banyak dengan Variasi Tata Letak Dinding Geser. Jurnal Sipil Statik, 3(6), 435–447.

PKS Sumbar. (2015). Sebagian Pembangunan Akibat Gempa Bumi 30 September 2009. Artikel online: https://sumbar.pks.id/2015 /04/sebagian-pembangunan-akibat-gempa-bumi.html. Diakses tanggal. 17 Agustus 2023.

Pramesti, N. R. (2018). Analisa Perilaku Bangunan Tidak Beraturan Horizontal dengan Variasi Dimensi Kolom Terhadap Gempa. Skripsi. Program Studi Pendidikan Teknik Bangunan Fakultas Teknik Universitas Negeri Jakarta.

Ramadhan, P., Purwandito, M., & Irwansyah. (2021). Kajian Penempatan Dinding Geser pada Gedung Rusun Berlantai 5 dengan Variasi Frame Walls. Jurnal Media Teknik Sipil Samudra, 2(2), 58–65.

Sari, N. W., Sulandari, S., & Lituhayu, D. (2014). Mitigasi Gempa dan Tsunami di Kota Padang. Tesis. Jurusan Administrasi Publik Fakultas Ilmu Sosial dan Ilmu Politik Universitas Diponegoro, Semarang.

SNI 1726-2019. Tata cara perencanaan ketahanan gempa untuk struktur bangunan gedung dan nongedung. Badan Standarisasi Nasional Indonesia, Jakarta.

Soelarso, Baehaki, & Novtikania, F. (2016). Analisis Perbandingan Simpangan Horisontal (Drift) pada Struktur Gedung Tahan Gempa dengan Menggunakan Pengaku Lateral (Bracing) Berdasarkan SNI 03-1726-2002 dan SNI 03-1726-2012. Jurnal Fondasi, 5(1), 24–34.

Soeprapto, S. (2015). Analisis Kesiapsiagaan Masyarakat Kota Padang Dalam Menghadapi Bencana Alam. Statistik Pusdatinmas BNPB.

Usmat, N. A., Imran., & Sultan, M. A. (2019). Analisa Letak Dinding Geser (Shear Wall) Terhadap Perilaku Struktur Gedung Akibat Beban Gempa. Techno: Jurnal Penelitian, 8(2), 297–307.

Wijayana, H., Susanti, E., & Septiarsilia, Y. (2020). Studi Perbandingan Letak Shear Wall terhadap Perilaku Struktur dengan menggunakan SNI 1726:2019 dan SNI 2847:2019. Seminar Nasional Sains dan Teknologi Terapan VIII 2020 Institut Teknologi Adhi Tama Surabaya.

Published
2023-08-19
How to Cite
Sudarmaka, I., Imani, R., Nasmirayanti, R., & Sari, K. (2023). RESPON STRUKTUR TERHADAP BEBAN DINAMIK GEMPA PADA RUSUN MAHASISWA INSTITUT TEKNOLOGI PADANG DENGAN SHEARWALL. JURNAL RIVET, 3(01), 20-28. https://doi.org/10.47233/rivet.v3i01.1023
Section
Articles